REU 3 Speed control. A single-phase transformer which controls the fan speed by altering the supply voltage in five fixed steps. The steps are adjusted manually, using the control knob on the front of the unit. There are two control switches: one for higher fan speeds and one for lower fan speeds. Switching between the high and low settings is done by an external change-over contact, which could be a thermostat or a timer. The indicator lamp on the front shows when the transformer is in operation. The fuse may be reset from outside. The REU has a self-extinguishing thermoplastic casing. Supply voltage: 230V 50/60Hz. NOTE! Fans with external thermal contact leads (TK) must always be connected to a motor protection device.
Additional Details
Additional Details
Delivery
This item is usually stocked overseas and takes about 2-3 weeks to deliver. If stock in UK deliverable in 3-4 days. Enquire on 01609 243164
Jumbo heaters have long been recognised as one of the best mobile diesel fired heaters in the market. We examine this revamped classic range of heaters
Average The Room Is A Normal Residential Room, Office, Reception Area Or Similar, Where There Is Not Overly Crowded With People, Computer And Office Equipment.
Above Average There Are Factors That Contribute To Additional Heat Being Generated In The Room E.G. Strong Lighting, Overcrowding With People And Office Equipment, Conservatory Type Room, Or Flat Roofed Room.
High There Are Factors That Contribute To A High Heat Load In The Room. E.G. Commercial Cooking, Much Computer And Server Equipment, Switchgear, Temporary Building With Thin Walls And Flat Room, Plain Glass Conservatory.
The Total Average Pressure Drop Over Your Higher Efficiency Filters And/Or Carbon Filters Is;
Pascals
This Pressure Drop Is Costing In Energy Alone
£
Per year
It Is Probable That A Sanuvox In-Duct System Could Break Down The Biological, Chemical And Odourous Contaminants On This Air Flow For Between 16 And 25% Of This Running Cost
£
Lower energy cost estimate of an equivalent Sanuvox system (16%)
£
Higher energy cost estimate of an equivalent Sanuvox system (25%)
This calculator is provided as a broad based indication of the energy cost of running a filter based air purification, and an indicative cost of running a Sanuvox system as an alternative. It should not be assumed to be absolutely accurate and should not be used as the basis of an actual system design or forecast of cost saving of an actual system. We accept no liability for consequences of the inappropriate use of this calculator, or its results. Actual figures would depend on the proposed system for a particular application and on the exact parameters of that application.