prio 200E2 circular duct fan. The prioAir series is designed for installation in ducts. PrioAir fans have 25 mm long spigot connections in acc. with EN 1506:1997. The fans have aerodynamically optimized impellers and guide vanes with intergrated external rotor motors. The fans can be speed-controlled via a stepless thyristor or a 5-step transformer. To protect the motor from overheating the fan has integrated thermal contacts with manual reset in acc. with EN 60335-2-80. The air tight casing (tightness class C in acc. with EN12237:2003) is manufactured from special composite material. The mounting clamp facilitates easy installation and removal, and prevents the transfer of vibrations to the duct. Mounting bracket to the wall or ceiling as accessory.
For installation in damp locations we recommend to use a run-on timer.
Additional Details
Additional Details
Delivery
This item is usually stocked overseas and takes about 2-3 weeks to deliver. If stock in UK deliverable in 3-4 days. Enquire on 01609 243164
9th April 2019 - The Master BCF range of industrial evaporative coolers bring greater versatility to the moulded plastic 'one size' evaporative coolers market.
Average The Room Is A Normal Residential Room, Office, Reception Area Or Similar, Where There Is Not Overly Crowded With People, Computer And Office Equipment.
Above Average There Are Factors That Contribute To Additional Heat Being Generated In The Room E.G. Strong Lighting, Overcrowding With People And Office Equipment, Conservatory Type Room, Or Flat Roofed Room.
High There Are Factors That Contribute To A High Heat Load In The Room. E.G. Commercial Cooking, Much Computer And Server Equipment, Switchgear, Temporary Building With Thin Walls And Flat Room, Plain Glass Conservatory.
The Total Average Pressure Drop Over Your Higher Efficiency Filters And/Or Carbon Filters Is;
Pascals
This Pressure Drop Is Costing In Energy Alone
£
Per year
It Is Probable That A Sanuvox In-Duct System Could Break Down The Biological, Chemical And Odourous Contaminants On This Air Flow For Between 16 And 25% Of This Running Cost
£
Lower energy cost estimate of an equivalent Sanuvox system (16%)
£
Higher energy cost estimate of an equivalent Sanuvox system (25%)
This calculator is provided as a broad based indication of the energy cost of running a filter based air purification, and an indicative cost of running a Sanuvox system as an alternative. It should not be assumed to be absolutely accurate and should not be used as the basis of an actual system design or forecast of cost saving of an actual system. We accept no liability for consequences of the inappropriate use of this calculator, or its results. Actual figures would depend on the proposed system for a particular application and on the exact parameters of that application.