AFilter cassette designed for bagFilters standard type F5 or F7. The cassette housing is manufactured from galvanised sheet steel. It has a hinged cover underneath fitted with a quickrelease latch, which makes it easy to replace theFilter. TheFilter cassette can be connected directly on to the duct and should always be fitted in a flat or vertical position. If fitted vertically, the direction of the air flow must be downwards so that theFilter bags do not collapse. BFKFilter media, in the F5 or F7Filter classes, are ordered separately and supplied individually. The recommended final pressure drop is 200 Pa for the F5Filter and 250 Pa for the F7Filter. The cassette is fitted with connections for connecting to a pressure sensor.
Additional Details
Additional Details
Delivery
This item is usually stocked overseas and takes about 2-3 weeks to deliver. If stock in UK deliverable in 3-4 days. Enquire on 01609 243164
Average The Room Is A Normal Residential Room, Office, Reception Area Or Similar, Where There Is Not Overly Crowded With People, Computer And Office Equipment.
Above Average There Are Factors That Contribute To Additional Heat Being Generated In The Room E.G. Strong Lighting, Overcrowding With People And Office Equipment, Conservatory Type Room, Or Flat Roofed Room.
High There Are Factors That Contribute To A High Heat Load In The Room. E.G. Commercial Cooking, Much Computer And Server Equipment, Switchgear, Temporary Building With Thin Walls And Flat Room, Plain Glass Conservatory.
The Total Average Pressure Drop Over Your Higher Efficiency Filters And/Or Carbon Filters Is;
Pascals
This Pressure Drop Is Costing In Energy Alone
£
Per year
It Is Probable That A Sanuvox In-Duct System Could Break Down The Biological, Chemical And Odourous Contaminants On This Air Flow For Between 16 And 25% Of This Running Cost
£
Lower energy cost estimate of an equivalent Sanuvox system (16%)
£
Higher energy cost estimate of an equivalent Sanuvox system (25%)
This calculator is provided as a broad based indication of the energy cost of running a filter based air purification, and an indicative cost of running a Sanuvox system as an alternative. It should not be assumed to be absolutely accurate and should not be used as the basis of an actual system design or forecast of cost saving of an actual system. We accept no liability for consequences of the inappropriate use of this calculator, or its results. Actual figures would depend on the proposed system for a particular application and on the exact parameters of that application.