Get in Touch

Call us or email with your enquiry and we can get the right product for you.

CEILFIT 1200 5995911

Overview

• 590mm x 1190mm
• non insulated
• 689w heating at 80° delta T
• 400w heating at 50° delta T
• 87w cooling at 10° delta T

Product Code: 5995911
Details

Radiant heating is based on the principle of the heat transfer of a warm body to a body with a lower temperature by means of electromagnetic wave energy. This electromagnetic wave is not hindered by air, radiates walls, floor and other bodies in the specific room. These items absorb the radiation energy and then pass the heat on to the heat air stream.

This produces a convective flow of slowly rising warm air and colder air falling again that blend (induction).

The heating of the air in the space takes place substantially by this convective air flow from the heated floor and walls. Heating a room by means of radiant panels always causes the floor temperature to be a few degrees higher than the room air temperature which in turn is experienced as very comfortable. Even directly under the radiation panel, the vertical temperature gradient is very low.

As the roof is often the largest surface that is directly in contact with the outside air, with air heating more energy will be lost by heating this cold surface.

Although this can be overcome by an increazed air circulation, however, this requires extra energy and leads to a higher air displacement.

Consequence: drafts and dust displacement. Floor and walls remain cold!

COMFORT

When our body gives more heat to its environment than it produces, we experience this as uncomfortable.

The ideal method to heat cold surfaces is by means of radiant panels mounted on the ceiling which transfer their heat mainly through radiation.

Persons who are radiated in a room experience less heat loss and therefore greater comfort. As a result, the room air tem_x001f_perature may be set a few degrees lower. This way, in addition to more comfort energy saving can be realized.

ZONE OR LOCALISED HEATING

Radiant heating is also ideal for zone or local heating. Only the area to be heated is radiated. As a result, the energy costs are limited to a minimum.

SYSTEM BENEFITS

  • Fast controllability by a low water content.
  • Uniform temperature distribution all over the horizontal area.
  • Very low vertical temperature gradient.
  • Zone or local heating is possible.
  • Still air layer, no dust or drafts.
  • Room temperature is 3C lower than heating by radiators or air heating.
  • 25-30% energy savings compared to conventional air heating.
  • 15% less full load hours.
  • Very long life.
  • Completely maintenance free.
  • Great comfort by direct radiation.
  • Heated floor.
  • Space saving.
  • Can be applied everywhere due to unobtrusive design

The Mark CEILFIT gives a comfortable work and living environment through heating and cooling by convection and radiation. It is easy to regulate zones or rooms individually to ensure a pleasant surrounding. Due to the exclusion of radiators, extra wall and floor space is made available.

Our panels are compatible with grid type ceilings and can replace the standard tile without any additional work to the grid. The standard panels are available in common standard grid dimension, or as custom dimensions on request.

The Mark CEILFIT is constructed of RAL 9010 powder coated 0,7 mm steel sheet fused to copper tube. The copper tubing allows a quick and efficient heat or cooling transfer. The copper tubing is a 10x0,4mm high quality precision tubing that can withstand pressure up to 6 bar.

Panels can be optionally insulated with mineral wool with an aluminium foil layer. Dummy panels can be fitted to accomodate lightning, sensors, ventilation or other additions to the ceiling.

The panels are also available with perforation for a better sound absorption.

To support the weight of a fluid filled panel we strongly advise to add suspension wires from the panels to a structural part of the building or ceiling. The panels are accomodated with several holes to fix the supension brackets or cables.

The Mark CEILFIT can be used in offices, schools, hospitals, public buildings and clinics.

All CEILFIT products are in accordance with the NEN-EN 13964 regulation.

Additional Details
Additional Details
Delivery Normally 5-7 working days. Expect within 9 working days of order
Brand Mark
Warranty 1 year manufacturers warranty