The latest addition to our Mighty Heat range is the FF80, a category leading 80kW heater capable of delivering massive volumes of warm air. Manufactured here in the UK, the FF80 is designed and built to withstand the rigors associated with industrial use. With a powerful backward curved impeller housed in an all steel chassis, the FF80 is an industrial heater that delivers 80kW of dry, safe, fume free heat at up to 6000m 3 /hr against a pressure drop of 600 Pa. With this sort of performance the FF80 is capable of ducting warm air great distances, allowing it to deliver heat whilst being positioned remotely.
Heating Capacity
79.5kw
Power supply
400v 3ph+N+E 125A 50Hz
Max running current
19.5Amp
Airflow Max
6000m3/hr
Weight
245kg
Noise level @ 3m
76 dB(A)
Max operating temperature
40°C +/-3
Max length of duct
100m
Temperature rise at 19°C ambient
53°C
IP rating
IP20
Additional Details
Additional Details
Delivery
Dependant on stock availability. Check with us before ordering
Average The Room Is A Normal Residential Room, Office, Reception Area Or Similar, Where There Is Not Overly Crowded With People, Computer And Office Equipment.
Above Average There Are Factors That Contribute To Additional Heat Being Generated In The Room E.G. Strong Lighting, Overcrowding With People And Office Equipment, Conservatory Type Room, Or Flat Roofed Room.
High There Are Factors That Contribute To A High Heat Load In The Room. E.G. Commercial Cooking, Much Computer And Server Equipment, Switchgear, Temporary Building With Thin Walls And Flat Room, Plain Glass Conservatory.
The Total Average Pressure Drop Over Your Higher Efficiency Filters And/Or Carbon Filters Is;
Pascals
This Pressure Drop Is Costing In Energy Alone
£
Per year
It Is Probable That A Sanuvox In-Duct System Could Break Down The Biological, Chemical And Odourous Contaminants On This Air Flow For Between 16 And 25% Of This Running Cost
£
Lower energy cost estimate of an equivalent Sanuvox system (16%)
£
Higher energy cost estimate of an equivalent Sanuvox system (25%)
This calculator is provided as a broad based indication of the energy cost of running a filter based air purification, and an indicative cost of running a Sanuvox system as an alternative. It should not be assumed to be absolutely accurate and should not be used as the basis of an actual system design or forecast of cost saving of an actual system. We accept no liability for consequences of the inappropriate use of this calculator, or its results. Actual figures would depend on the proposed system for a particular application and on the exact parameters of that application.