DVG smoke and heat extract fans are used in case of fire to extract smoke gases from rooms, and also during normal working conditions for standard ventilation. Smoke-free escape ways increase the chances to rescue people in case of fire. The casing is manufactured from seawater resistant aluminium. The base frame is made of pre-galvanised steel, zinc-magnesium (ZM) coated. Impeller with backward-curved blades is manufactured from pre-galvanized steel (sizes 355, 450), respectively from steel, welded and galvanised. Motor outside air stream is cooled with fresh air. Electric motor of IE1 standard efficiency, single or two speed, respectively IE2 high efficiency single speed motor at 4 and 6 pole fans from 0,75 kW output power. PTC serial built-in. For two speed fans (up to 4 kW) two speed switch is available as accessory (in this case thermal contact must be ordered; not suitable for PTC or without thermal contact). In case of fire eventual two speed switch and all motor protective devices must be bridged to guarantee functional capability (connection direct to the mains). For speed control use only frequency converter (please see instructions for details). Not suitable for voltage control. If frequency converter used in case of fire, PTC must be bridged and switching on max. speed even after eventual short supply cut off assured. Operating over 50 Hz is allowed at units on request only. At frequency controlled units additional EMC protection could be needed (on request). Please observe capability of service switch for cable connection. The data of input power and current may slightly vary due to different motor supllier.
Additional Details
Additional Details
Delivery
This item is usually stocked overseas and takes about 2-3 weeks to deliver. If stock in UK deliverable in 3-4 days. Enquire on 01609 243164
Average The Room Is A Normal Residential Room, Office, Reception Area Or Similar, Where There Is Not Overly Crowded With People, Computer And Office Equipment.
Above Average There Are Factors That Contribute To Additional Heat Being Generated In The Room E.G. Strong Lighting, Overcrowding With People And Office Equipment, Conservatory Type Room, Or Flat Roofed Room.
High There Are Factors That Contribute To A High Heat Load In The Room. E.G. Commercial Cooking, Much Computer And Server Equipment, Switchgear, Temporary Building With Thin Walls And Flat Room, Plain Glass Conservatory.
The Total Average Pressure Drop Over Your Higher Efficiency Filters And/Or Carbon Filters Is;
Pascals
This Pressure Drop Is Costing In Energy Alone
£
Per year
It Is Probable That A Sanuvox In-Duct System Could Break Down The Biological, Chemical And Odourous Contaminants On This Air Flow For Between 16 And 25% Of This Running Cost
£
Lower energy cost estimate of an equivalent Sanuvox system (16%)
£
Higher energy cost estimate of an equivalent Sanuvox system (25%)
This calculator is provided as a broad based indication of the energy cost of running a filter based air purification, and an indicative cost of running a Sanuvox system as an alternative. It should not be assumed to be absolutely accurate and should not be used as the basis of an actual system design or forecast of cost saving of an actual system. We accept no liability for consequences of the inappropriate use of this calculator, or its results. Actual figures would depend on the proposed system for a particular application and on the exact parameters of that application.